Edition Rev 0
28-10
FUEL SYSTEM MAINTENANCE PRACTICE
3. FUEL QUANTITY SENDER REPLACEMENT
Step
Task description
Additional note
1.
Engage parking brake
2.
Set Master Switch OFF. Pull out fuel q.ty breakers.
3.
Drain fuel tank according to Fuel system draining
procedure
See Chapter 12
4.
Unscrew fuel q.ty sender cap from wing upper chamber in
correspondence of fuel tank (cap 21)
See Chapter 6
5.
Unscrew along fuel q.ty sender flange and disconnect
ground connector
Refer to Figures 8.
and 9.
6.
Remove fuel sender and replace (if needed)
7.
Reconnect ground connector to fuel sender
Refer to Figures 9.
8.
Screw fuel sender on its housing and reapply cap (cap 21)
See Chapter 6 and
Figure 8.
9.
Refill fuel tank
10.
Make a fuel qty. test procedure according par. 01
Refer to par. 01