POWER GENERATION MAINTENANCE PRACTICE
Apply the following procedure for GILL G25 battery use and recharge:
Step no.
Battery use and recharge
Task description
Additional info &
References
1.
Check the voltage
In open circuit mode
2.
If the voltage is 10,60 (or higher) the battery is
proper charged and ready to install on aircraft
3.
If the voltage is lower than 10,60 in one of the
following situations:
- Dry charge new battery 10-12 hours after
having filled up with acid
- Battery already in use, which as remained
inactive for long time
For battery recharge,
refer to step 4. Of
these table
4.
For constant voltage charging procedure:
- Constant voltage range = 14,40-15,00 V
- Charging time = min. 6 hours max 12 hours
NEVER CHARGE THE BATTERY OVER 24 Hours