Page 203 2
nd
Edition – Rev 0
24-10
POWER GENERATION – MAINTENANCE PRACTICE
Apply the following procedure for GILL G25 battery use and recharge:
Battery use and recharge
Task description
Additional info &
References
If the voltage is 10,60 (or higher) the battery is
proper charged and ready to install on aircraft
If the voltage is lower than 10,60 in one of the
following situations:
- Dry charge new battery 10-12 hours after
having filled up with acid
- Battery already in use, which as remained
inactive for long time
For battery recharge,
refer to step 4. Of
these table
For constant voltage charging procedure:
- Constant voltage range = 14,40-15,00 V
- Charging time = min. 6 hours – max 12 hours
NEVER CHARGE THE BATTERY OVER 24 Hours