The instruction to make repairs or replacements of inspected items can be found
in the related component/system ATA Chapter.
A log book entry should be made upon completion of any inspections
For checks and inspections to be carried out, refer to the following general rules:
MOVABLE PARTS for lubrication, security of attachment, safetying, excessive
wear, correct travel, cracked fittings, safety of hinges, defective bearings, cleanli-
ness, corrosion, deformation and tension.
FLUID LINES and HOSES for leaks, cracks, dents, kinks, chafing, proper radius,
corrosion, obstructions and deterioration.
METAL PARTS for security of attachment, cracks, metal distortion, broken
spotwelds and riveting, corrosion and any other apparent damage
WIRING for security, chafing, burning, defective insulation , loose or broken
terminals, heat deterioration.
BOLTS for correct torque, safetying and damaged thread
FILTERS and FLUID for cleanliness, contamination and/or replacement if re-
quired.
Make sure that all Airworthiness Directives and Service Bulletins are implement-
ed as required. Tecnam can change the time between checks publishing the
change as a revision of this Maintenance Manual.