TEEJET 5000 OPERATORS MANUAL FERTILISER DISTRIBUTOR, RAUCH BETA/DELTA
4.107
EMPTY
HOPPER: To ease emptying the hopper. The gate can be opened completely
by pressing this key (only found in the BETA program).
RPM: Pressing this key displays the disc speed. The minimum and
maximum speed at which an alarm may be given for disc speed is
set under “ENCODE”.
AUTO/MAN: Pressing this key changes between automatic and manual
application control. During manual operation “MAN” flashes at the
bottom of the display.
Pressing the “NEXT PAGE” key displays the next functions.
+: Increased application rate.
-: Decreased application rate.
POS.: Actuator position (gate opening).
+: Each key press increases the application rate. If the key remains
pressed then the application rate is increased by a suitable
amount. The actual application rate can be seen on the display.
-: Each key press decreases the application rate. If the key remains
pressed then the application rate is decreased by a suitable
amount. The actual application rate can be seen on the display.
POS.: Pressing this key displays the gate position, changes between the
left- and right-hand side.