SEED DRILL, LEMKEN TEEJET 5000 OPERATORS MANUAL
5.56
WORK HOUR ON/OFF
Select whether the timer function is started/stopped manually via the function key
in the operation menu or by the selected implement sensor.
PTO SENSOR
Encode the number of pulses per revolution for the PTO sensor (encode 1 if the
TeeJet PTO sensor kit (932-983) is used).
WARNINGS
The following warnings can be set in this menu:
It is recommended to turn all warnings, which are not wanted “OFF”.
PTO: Warning ON/OFF and MAX/MIN-limits for revolutions.
KM/H: Warning ON/OFF and MAX/MIN-limits for speed.
KG
LEFT: Warning ON/OFF and amount of kg (min.) in the hopper at which the
warning is wanted.
D. SHAFT: Warning ON/OFF if the drill shaft stops turning.
HOPPER: Warning ON/OFF for empty seed hopper.
RPM: Warning ON/OFF and MIN/MAX-limits for fan RPM
NB: If the warning for RPM is “on” then the computer will not allow
sowing to commence before it receives signals from the fitted RPM
sensor.
If the warning is “off” then sowing is independent of the RPM sensor.
WARN DOSE AREA
The dose rate warning is a fixed warning, which cannot be switched off. As the
program is used for a number of different seed drills, used under various working
conditions it is possible to set the warning so that unwanted warnings are not
given. This is done under the main menu for the Lemken seed drill program.