SEED DRILL, SIMBA TEEJET 5000 OPERATORS MANUAL
5.74
WARNING ENCODE
The following warnings can be set in this menu:
It is recommended to turn all warnings, which are not wanted “OFF”.
PTO: Warning ON/OFF and MAX/MIN-limits for revolutions.
KM/H: Warning ON/OFF and MAX/MIN-limits for speed.
SLIP: Warning ON/OFF and MAX/MIN-limits for wheel slip in %.
KG
LEFT: Warning ON/OFF and amount of kg (min.) at which the warning is
wanted.
D. SHAFT: Warning ON/OFF if the drill shaft stops turning.
HOPPER: Warning ON/OFF for empty seed hopper.
FAN: Warning ON/OFF and MAX/MIN-limits for revolutions.
DATE - CLOCK:
Set the date and time in this menu:
HOURS - MINUTES - YEAR - MONTH – DAY.