SLURRY SPREADER, OTHER TYPE (HYDR.) TEEJET 5000 OPERATORS MANUAL
7.22
FILLED VOLUME
Encode the amount filled if the tank is only filled, e.g. half way up. Must be
encoded when the amount filled differs from the TANK VOLUME. Pressing “FULL
TANK” automatically transfers the amount encoded under TANK VOLUME.
Remember: to encode the amount filled before leaving encode.
HA LEFT
Encode the size of the field to be spread here. END TIME, is calculated from this
encodement.
FLOW FIGURE
CALIBRATION:
NOTE: Encode a “start value” of 1000.
Automatic calibration:
1. Fill the slurry spreader to the top, so that you know
the exact amount.
2. Encode the amount in “FILLED VOLUME”.
3. Empty the tank completely, but be sure to stop
emptying as soon as the tank is empty, as air going
through the flowmeter can cause false readings.
4. Encode 0.00 using the numerical keypad under
“TANK REM. VOL.
5. Press the flashing “CALC. FLOW” key.
6. The flow figure is calculated.
NOTE: Greater accuracy can be achieved by
weighing the loads. A new flow figure is
calculated each time “CALC. FLOW” is
pressed.