TEEJET 5000 OPERATORS MANUAL SLURRY SPREADER, HORSCH
7.35
Manual calibration:
The flow figure can also be calculated manually, as follows:
1. Fill the slurry spreader to the top, so that you know the exact amount
2. Reset the amount counter in “DATA/DELETE”.
3. Empty the tank completely.
4. Read the amount in “DATA/DELETE”.
5. Place the value in the following formula:
Old flow figure x the amount spread
NEW FLOW FIGURE =
The amount read in Data/delete (TeeJet
5000)
6. Encode this new flow figure using the numerical keypad.
BOOM WIDTH
The working width of the spreader. If the system is fitted with control valves for
each section, then the individual section width must be encoded here (left = boom
section 1). If the spreader does not have individual sections, then encode the
whole spreader width as section 1 (all other sections must be encoded as 0).
UNIFORM PRESSURE
If the spreader’s distribution head is fitted with uniform pressure valves (return to
tank) or not.
ON = YES
OFF = NO