TEEJET 5000 OPERATORS MANUAL SLURRY SPREADER, OTHER TYPE (HYDR.)
7.21
SLURRY SPREADER ENCODE
This menu allows the operator to encode the various settings that are necessary
for spreading. Each implement has it’s own set of encodements. Encodements
such as speed sensor (and its calibration) have their own values under each
implement.
Always check these encodements in the status screen each time you change
implements.
DOSE RATE
The required application rate is encoded here. Encode the required application
rate in TONS or M3 (cubic metres) per hectare. If TON/HA is selected, then the
specific gravity of the slurry must also be encoded. Moving the cursor to
SPECIFIC GRAVITY and then encoding the value using the numerical keypad
does this. The maximum application rate that can be encoded is 99.9. Pressing
the “M3/TON” key changes between TON or M3.
STEP %:
Encode the size of the steps for the “STEP” function. This % value is the same for
both + and -. The maximum step size is 99%.
TANK VOLUME
Encode the effective tank size here. Used in connection with “FULL TANK” in
operation.
Check by weighing some loads to get the effective TANK VOLUME.