TEEJET 5000 OPERATORS MANUAL SEED DRILL, LEMKEN
5.35
RPM: Fan Speed.
VALVE
RPM: Regulating motor speed
RPM: Fan speed displayed in revolutions per minute.
VALVE
RPM: Regulating motor speed displayed in revolutions per minute.
Selecting this function display's, both the “desired” motor speed
calculated from the actual forward speed, the actual seed rate and
the actual regulating motor speed.
Pressing the “NEXT PAGE” key displays the next available functions:
MANUAL
START: Manual start and stop of the regulating
motor.
TRACK+1: Moves one step forward in the tramline
rhythm.
TRACK-1: Moves one step backwards in the
tramline rhythm.
MANUAL
START: This function is used to start or stop the drill shaft motor manually.
“MANUAL START” can only be used if the machine is at a
standstill. The display will change to “MANUAL STOP” as soon
as the computer receives a signal from a forward speed sensor.
Manual start can be used in difficult conditions, i.e. corners, etc.
and ensures total coverage of the field. Pressing the key turns the
drill shaft for a number of seconds (each key press turns the drill
shaft for the number of seconds encoded under “ENCODE” max.
20 seconds).
Pressing the “MANUAL STOP” key stops the drill shaft from
rotating instantly. This function can be used on pneumatic seed
drills where the seed route is so long that the tubes are not empty
before the drill is raised.
The seed drill must
be raised each time “MANUAL STOP” has
been used.
TRACK+1: Moves one-step forward in the tramline rhythm.
TRACK-1: Moves one step backward in the tramline rhythm.
Pressing the “NEXT PAGE” key displays the first available functions:

Table of Contents