5
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of the NC.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 2.
6
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of SSC 1.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 3.
7
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of SSC 1.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 3.
8
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port that corresponds to the control card in Slot1 of SSC 2.
b
Plug the other connector into the M-MSM-1 port that corresponds to the control card in Slot 1 of the
SSC 4.
9
Using another cross-over (CAT-5) LAN cable:
a
Plug one connector into the P-MSM-1 port that corresponds to the control card in Slot 17 of SSC 2.
b
Plug the other connector into the P-MSM-1 port that corresponds to the control card in Slot 17 of the
SSC 4.
10
Connect the remaining SSCs by repeating Steps 6 through 9.
Cisco NCS 2000 Series Hardware Installation Guide
421
Multishelf Management
Cisco NCS 2015 Node Controller (NC) and NCS 2015 Subtending Shelves (SSC)