d
RJ-45 port of the control card in Slot 7 of ONS 15454 SSC.
e
Plug the other end into Port 2 of the active Catalyst 3560.
f
Using a cross-over (CAT-5) LAN cable, plug one connector into:
g
P-MSM-1 port of NCS 2015 SSC that corresponds to the control card in Slot 17
h
MSM port of NCS 2006 SSC that corresponds to the control card in Slot 8.
i
RJ-45 port of the control card in Slot 11 of ONS 15454 SSC.
j
Plug the other end into Port 2 of the standby Catalyst 3560.
5
To configure the active and standby Catalyst 3560, complete the NTP-L63 Configure a Cisco Catalyst
3560 (Active and Standby) for a Multishelf Node, on page 413.
Cisco ONS 15454 Node Controller, and ONS 15454, NCS 2006, and NCS 2015
Subtending Shelves
When a Cisco ONS 15454 shelf is used as the node controller, a mix of 15 ONS 15454, NCS 2006, and NCS
2015 shelves can be subtended. The maximum number of NCS 2015 shelves that can be subtended is 10.
The control cards supported are:
•
NCS 2015 shelf: TNCS, TNCS-O
•
NCS 2006 shelf: TNCE, TSCE, TNCS, TNCS-O
•
ONS 15454 shelf: TCC3
Usage of TCC3 card as the node controller is recommended.Note
•
The software package supported in this topology is the Cisco ONS 15454 DWDM package.
Scenario 1: Using RJ-45 and SFP MSM-M and MSM-P Ports, ONS 15454, NCS 2006 and NCS
2015 SSCs Can Be Connected to the ONS 15454 NC.
When an ONS 15454 is used as the node controller, a mix of 15 ONS 15454, NCS 2006, and NCS 2015
shelves can be subtended through the MS-ISC-100T card connected to the node controller.
1
To connect the ONS 15454 NC to two MS-ISC-100T cards, complete the NTP-L64 Connect the ONS
15454 Node Controller to an MS-ISC-100T Card, on page 415.
2
To configure the MS-ISC-100T cards, complete the NTP-L65 Configure the MS-ISC-100T Card for a
ONS 15454 Multishelf Node for Non-Default Public and Private VLAN IDs, on page 417.
3
To install the SFP module in the SFP ports of the ECU in NCS 2015 SSCs, complete the NTP-L62 Installing
the SFP Module on the NCS 2015 ECU, on page 412.
4
Using a cross-over (CAT-5) LAN cable:.
a
Plug one connector into the SSC1 port on the left EAP.
b
Plug the other end of the connector into one of the following:
c
MSM port of the NCS 2006 SSC that corresponds to the control card in Slot 1.
d
RJ-45 port of the control card in Slot 1 of ONS 15454 SSC.
Cisco NCS 2000 Series Hardware Installation Guide
430
Multishelf Management
Cisco ONS 15454 Node Controller, and ONS 15454, NCS 2006, and NCS 2015 Subtending Shelves

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2006 and is the answer not in the manual?

Cisco NCS 2006 Specifications

General IconGeneral
BrandCisco
ModelNCS 2006
CategoryNetwork Hardware
LanguageEnglish

Related product manuals