b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 2.
5
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of the NC.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 2.
6
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of SSC 1.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 3.
7
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of SSC 1.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 3.
8
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of SSC 2.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 4.
9
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of SSC 2.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 4.
10
Connect the remaining SSCs by repeating Steps 6 through 9.
Scenario 4: Using Cisco Catalyst Switch 3650, Up to 10 NCS 2015 SSCs Can Be Connected To
the NCS 2015 NC
1
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into Port 1 of the active Catalyst 3560.
b
Plug the other connector into the M-MSM-1 port of the NC.
2
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into Port 1 of the standby Catalyst 3560.
b
Plug the other connector into the P-MSM-1 port of the NC.
3
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into Port 23 of the active Catalyst 3560.
b
Plug the other end into Port 23 of the standby Catalyst 3560.
4
To connect a SSC to the Catalyst 3560 switches, use a cross-over (CAT-5) LAN cable.
a
Plug one connector into the M-MSM-1 port of the SSC.
Cisco NCS 2000 Series Hardware Installation Guide
423
Multishelf Management
Cisco NCS 2015 Node Controller (NC) and NCS 2015 Subtending Shelves (SSC)