b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 2.
5
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of the NC.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 2.
6
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of SSC 1.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 3.
7
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of SSC 1.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 3.
8
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of SSC 2.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 4.
9
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of SSC 2.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 4.
10
Connect the remaining SSCs by repeating Steps 6 through 9.
Scenario 4: Using Cisco Catalyst Switch 3650, Up to 10 NCS 2015 SSCs Can Be Connected To
the NCS 2015 NC
1
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into Port 1 of the active Catalyst 3560.
b
Plug the other connector into the M-MSM-1 port of the NC.
2
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into Port 1 of the standby Catalyst 3560.
b
Plug the other connector into the P-MSM-1 port of the NC.
3
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into Port 23 of the active Catalyst 3560.
b
Plug the other end into Port 23 of the standby Catalyst 3560.
4
To connect a SSC to the Catalyst 3560 switches, use a cross-over (CAT-5) LAN cable.
a
Plug one connector into the M-MSM-1 port of the SSC.
Cisco NCS 2000 Series Hardware Installation Guide
423
Multishelf Management
Cisco NCS 2015 Node Controller (NC) and NCS 2015 Subtending Shelves (SSC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2006 and is the answer not in the manual?

Cisco NCS 2006 Specifications

General IconGeneral
BrandCisco
ModelNCS 2006
CategoryNetwork Hardware
LanguageEnglish

Related product manuals