Page #448 background image
(Router(config)# crc 32
(Router(config)# ip classless
(Router(config)# no ip http server
Stop. You have completed this procedure.
Cisco NCS 2015 Node Controller (NC) and NCS 2015 Subtending Shelves (SSC)
When the NCS 2015 shelf is used as the NC, up to 10 NCS 2015 shelves can be subtended. The control cards
supported on the NCS 2015 shelf are TNCS and TNCS-O.
Scenario 1 : Using Only RJ-45 Ports, Only One NCS 2015 SSC Can Be Connected to the NCS
2015 NC
1
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port that corresponds to the control card in Slot 1 of the NC.
b
Plug the other connector into the M-MSM-1 port that corresponds to the control card in Slot 1 of the
SSC.
2
Using another cross-over (CAT-5) LAN cable:
a
Plug one connector into the P-MSM-1 port that corresponds to the control card in Slot 17 of the NC.
b
Plug the other connector into the P-MSM-1 port that corresponds to the control card in Slot 17 of the
SSC.
Scenario 2 : Using RJ-45 and SFP MSM-M and MSM-P Ports, Up to 10 NCS 2015 SSCs Can Be
Connected To the NCS 2015 NC
1
Install the SFP module in the SFP ports of the NCS 2015 ECU. For more information, see NTP-L62
Installing the SFP Module on the NCS 2015 ECU, on page 412.
2
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port that corresponds to the control card in Slot1 of the NC.
b
Plug the other connector into the M-MSM-1 port that corresponds to the control card in Slot 1 of the
SSC 1.
3
Using another cross-over (CAT-5) LAN cable:
a
Plug one connector into the P-MSM-1 port that corresponds to the control Slot 17 of the NC.
b
Plug the other connector into the P-MSM-1 port that corresponds to the control in Slot 17 of the SSC
1.
4
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of the NC.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 2.
Cisco NCS 2000 Series Hardware Installation Guide
420
Multishelf Management
Cisco NCS 2015 Node Controller (NC) and NCS 2015 Subtending Shelves (SSC)