EasyManuals Logo

Cisco NCS 2006 User Manual

Cisco NCS 2006
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #494 background imageLoading...
Page #494 background image
Nominal: –48 VDC◦
â—¦
Input Voltage Range: -40.5 to -57.6 VDC
•
Power terminals: DSUB 2 poles for ETSI applications and terminal block double pole for applications
•
External fuse must not exceed 15A
•
Total maximum power consumption of 450W with ancillaries, controllers and linecards
Fan Tray
The following table lists power requirements for the fan-tray assembly.
Table 23: Fan-Tray Assembly Power Requirements
BTU/HrAmpsWattsFan Tray Assembly
120135NCS2002-FTA
System Environmental Specifications
The NCS 2002 for ANSI environment has these specifications:
•
Operating temperature: 23 to +131 degrees Farenheit (-5 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
The NCS 2002 for ETSI environment has the following specifications:
•
Operating temperature: 23 to 131 degrees Fahrenheit (-5 to +55 degrees Celsius)
•
Operating humidity: 5 to 95 percent, noncondensing
Dimensions
The NCS 2002 shelf assembly has these dimensions:
•
Height: 3.5 inches (88.9 mm)
•
Width: 19 or 23 inches (482.6 or 584.2 mm) with mounting ears attached
•
Depth: 11.1 inches (281.94 mm)
•
Weight:
â—¦
11.02 pounds (5 kg) with preinstalled air filter and no cards installed
â—¦
15.40 pounds (6.82 kg) with the power module, fan-tray assembly and air filter installed but with
no cards.
Cisco NCS 2000 Series Hardware Installation Guide
466
Hardware Specifications
Fan Tray