b
Plug the other end into Port 2 of the active Catalyst 3560.
c
Using a cross-over (CAT-5) LAN cable, plug one connector into the P-MSM-1 port of the SSC.
d
Plug the other end into Port 2 of the standby Catalyst 3560.
5
Repeat Step 4 to connect the remaining SSCs using ports 3 through 11on the Catalyst 3560 switches.
6
To configure the active and standby Catalyst 3560, complete the NTP-L63 Configure a Cisco Catalyst
3560 (Active and Standby) for a Multishelf Node, on page 413
Cisco NCS 2015 Node Controller, ONS 15454, NCS 2006, and NCS 2015 as
Subtending Shelves
When a Cisco NCS 2015 shelf is used as the node controller, a mix of 15 ONS 15454, NCS 2006, and NCS
2015 shelves can be subtended. The maximum number of NCS 2015 shelves that can be subtended is 10.
The control cards supported are:
•
NCS 2015 shelf: TNCS, TNCS-O
•
NCS 2006 shelf: TNCE, TSCE, TNCS, TNCS-O
•
ONS 15454 shelf: TCC3
Scenario 1: Using RJ-45 and SFP MSM-M and MSM-P Ports, ONS 15454, NCS 2006, and NCS
2015 SSCs Can Be Connected to the NCS 2015 NC
1
Install the SFP module in the SFP ports of the ECU in NCS 2015 SSCs. For more information, see NTP-L62
Installing the SFP Module on the NCS 2015 ECU, on page 412.
2
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port of the NCS 2015 NC that corresponds to the control card
in Slot 1.
b
Plug the other end into the MSM port of the NCS 2006 SSC 1 that corresponds to the control card in
Slot 1.
3
Using another cross-over (CAT-5) LAN cable:
a
Plug one connector into the P-MSM-1 port of the NCS 2015 NC that corresponds to the control card
in Slot 17.
b
Plug the other end into the MSM port of the NCS 2006 SSC 1 that corresponds to the control card in
Slot 8.
4
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port that corresponds to the control card in Slot 1 of the NC.
b
Plug the other connector into the M-MSM-2 port that corresponds to the control card in Slot 1 of the
SSC 2.
5
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port that corresponds to the control card in Slot 17 of the NC.
b
Plug the other connector into the P-MSM-2 port that corresponds to the control card in Slot 17 of the
SSC 2.
Cisco NCS 2000 Series Hardware Installation Guide
424
Multishelf Management
Cisco NCS 2015 Node Controller, ONS 15454, NCS 2006, and NCS 2015 as Subtending Shelves

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2006 and is the answer not in the manual?

Cisco NCS 2006 Specifications

General IconGeneral
BrandCisco
ModelNCS 2006
CategoryNetwork Hardware
LanguageEnglish

Related product manuals