Wall Mounting the NCS 2002 Shelf
The NCS 2002 shelf can be mounted on the wall using the wall mount brackets. The type of screws used to
mount the brackets on the wall depends on the wall-type and are not provided by Cisco.
After the NCS 2002 shelf is mounted on the wall, a fire protective tray is installed on the wall mount bracket
to support the shelf.
NTP-L42 Installing the NCS 2002 Shelf
This procedure helps in mounting the NCS 2002 shelf.Purpose
•
#2 Phillips Dynamometric screwdriver
•
Medium slot-head screwdriver
•
Small slot-head screwdriver
•
ETSI only:
â—¦
Two M6 x 20 pan-head Phillips mounting
screws
•
ANSI only:
â—¦
Two #12-24 x 3/4 pan-head Phillips
mounting screws
Tools/Equipment
DLP-L62 Unpacking and Verifying the Shelf , on
page 20
DLP-L63 Inspecting the Shelf, on page 22
Prerequisite Procedures
RequiredRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to
the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack
to tip over. Statement 1048
Warning
Cisco NCS 2000 Series Hardware Installation Guide
65
Mounting the Cisco NCS 2002 Shelf
Wall Mounting the NCS 2002 Shelf