EasyManua.ls Logo

Cisco NCS 2006 - NTP-L20 Replacing the Air Filter of the NCS 2006 Shelf Assembly

Cisco NCS 2006
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Stop. You have completed this procedure.
NTP-L20 Replacing the Air Filter of the NCS 2006 Shelf Assembly
This procedure replaces the air filter of the NCS 2006
shelf assembly.
Purpose
New air filterTools/Equipment
NTP-L3 Mounting the NCS 2006 Shelf, on
page 189
Connect the chassis to the office ground. For
detailed instructions on how to ground the
chassis, refer to the Electrostatic Discharge and
Grounding Guide for Cisco NCS 2000 Series .
Prerequisite Procedures
As NeededRequired/As Needed
RemoteOnsite/Remote
Provisioning or higherSecurity Level
The air filters are single-use only. They must not be cleaned and reused. This is a Telcordia NEBS
requirement, GR-63-CORE Issue 4.
Note
Air filters must be inspected every quarter after the initial six month inspection. If they are dirty or clogged
with dust, they must be replaced with a new air filter.
Note
Cisco NCS 2000 Series Hardware Installation Guide
444
Maintaining the NCS 2002, NCS 2006, and NCS 2015 Shelves
NTP-L20 Replacing the Air Filter of the NCS 2006 Shelf Assembly

Table of Contents

Related product manuals