The figure below provides the dimensions of the NCS 2002 shelf installed on a 600 x 600-mm (23.6 x 23.6-inch)
ETSI standard equipment rack.
Figure 39: Cisco NCS 2002 Shelf Dimensions for an ETSI Rack Configuration
Mounting a Single Node
The NCS 2002 requires 3.5 inches (88.9 mm) minimum of vertical rack space. To ensure the mounting is
secure, use two to three 2006 mounting screws for each side of the shelf.
In an ETSI rack, the brackets can be mounted only in the front position.
The NCS 2002 shelves can be mounted above each other without any space between the shelves. This method
of mounting does not restrict the air flow because the air vents are on either sides of the NCS 2002 shelves.