4
Repeat Steps 2 and 3 to connect the remaining SSCs.
5
To complete the ring, plug one connector of a cross-over (CAT-5) LAN cable into P-MSM-1 port of NCS
2015 SSC 15. Plug the other connector into the P-MSM-1 port of the NC.
Scenario 4: Using RJ-45 and SFP MSM-M and MSM-P Ports Connect Cisco NCS 2015 Node
Controller, and ONS 15454, NCS 2006, and NCS 2015 as Subtending Shelves in a Ring Topology
The maximum number of NCS 2015 shelves that can be subtended is 10.
1
Install the SFP module in the SFP ports of the ECU in NCS 2015 SSCs. For more information, see NTP-L62
Installing the SFP Module on the NCS 2015 ECU, on page 412.
2
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port of the NCS 2015 NC that corresponds to the control card
in Slot 1.
b
Plug the other end into the MSM port of the NCS 2006 SSC 1 that corresponds to the control card in
Slot 1.
3
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the MSM port of the NCS 2006 SSC 1 that corresponds to the control card in
Slot 8.
b
Plug the other end into the P-MSM port of the NCS 2015 SSC 2 that corresponds to the control card
in Slot 17.
4
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port of the NCS 2015 SSC 2 that corresponds to the control
card in Slot 1.
b
Plug the other end into the RJ-45 port of the control card in Slot 7 of ONS 15454 SSC 3.
5
Repeat Steps 2 and 3 to connect the remaining SSCs.
6
To complete the ring, plug one connector of a multi-mode fiber optic cable into P-MSM-2 port of NCS
2015 SSC 15. Plug the other connector into the P-MSM-2 port of the NC.
Scenario 5: Using RJ-45 and SFP MSM-M and MSM-P Ports Connect Cisco NCS 2006 Node
Controller, and ONS 15454, NCS 2006, and NCS 2015 as Subtending Shelves in a Ring Topology
The maximum number of NCS 2015 shelves that can be subtended is 10.
1
Install the SFP module in the SFP ports of the ECU in NCS 2015 SSCs. For more information, see NTP-L62
Installing the SFP Module on the NCS 2015 ECU, on page 412
2
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the MSM port of the NCS 2006 NC that corresponds to the control card in
Slot 1.
Cisco NCS 2000 Series Hardware Installation Guide
436
Multishelf Management
Ring Topology

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NCS 2006 and is the answer not in the manual?

Cisco NCS 2006 Specifications

General IconGeneral
BrandCisco
ModelNCS 2006
CategoryNetwork Hardware
LanguageEnglish

Related product manuals