To create a ring topology using only SFP MSM ports, perform Steps 8 through 14.
3
To create a ring topology using a mix of RJ-45 MSM ports and SFP ports, perform Steps 15 through 18.
4
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into the M-MSM-1 port of the NC.
b
Plug the other connector into the M-MSM-1 port of the SSC 1.
5
Using a cross-over (CAT-5) LAN cable:
a
Plug one connector into P-MSM-1 port of SSC 1.
b
Plug the other connector into the P-MSM-1 port of the SSC 2.
6
Repeat Step 3 to connect the remaining SSCs.
7
To complete the ring, plug one connector of a cross-over (CAT-5) LAN cable into P-MSM-1 port of SSC
10. Plug the other connector into the P-MSM-1 port of the NC.
8
Using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-2 port of the NC that corresponds to the control card in Slot 1.
b
Plug the other connector into the M-MSM-2 port of SSC 1 that corresponds to the control card in Slot
1.
9
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-2 port of the NC that corresponds to the control card in Slot 17.
b
Plug the other connector into the P-MSM-2 port of the SSC 1 that corresponds to the control card in
Slot 17.
10
Using another multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-3 port of the SSC 1 that corresponds to the control card in Slot
1.
b
Plug the other connector into the M-MSM-2 port of the SSC 2 that corresponds to the control card in
Slot 1.
11
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-3 port of the SSC 1 that corresponds to the control card in Slot
17.
b
Plug the other connector into the P-MSM-2 port of the SSC 2 that corresponds to the control card in
Slot 17.
12
Repeat Steps 10 and 11 to connect all the SSCs.
13
To complete the ring, using a multi-mode fiber optic cable:
a
Plug one connector into the M-MSM-2 port of SSC 10 that corresponds to the control card in Slot 1.
b
Plug the other connector into the M-MSM-3 port of the NC that corresponds to the control card in Slot
1.
14
Using another multi-mode fiber optic cable:
a
Plug one connector into the P-MSM-2 port of the SSC 10 that corresponds to the control card in Slot
17.
b
Plug the other connector into the P-MSM-3 port of the NC that corresponds to the control card in Slot
17.
Cisco NCS 2000 Series Hardware Installation Guide
433
Multishelf Management
Ring Topology

Table of Contents

Related product manuals