#2 Phillips Dynamometric screwdriver
•
Medium slot-head screwdriver
•
Small slot-head screwdriver
•
Screws
â—¦
ANSI: #12-24 x 0.50 pan-head Phillips
screws
â—¦
ETSI: M6.0 x 20 pan-head Phillips screws
•
Wing head screws (4)
•
Adapter plates
•
One air plenum kit (horizontal and vertical air
plenums)
Tools/Equipment
As neededRequired/As Needed
OnsiteOnsite/Remote
NoneSecurity Level
Before performing any of the following procedures, ensure that power is removed from the DC
circuit. Statement 1074
Warning
Before working on a chassis or working near power supplies, unplug the power cord on AC units.
Statement 246
Warning
This equipment is intended to be grounded. Ensure that the host is connected to earth ground during
normal use. Statement 39
Warning
For nominal voltage of -60 VDC, the input voltage range is from -40 to -72 VDC.Note
Use only the fastening hardware provided with the NCS 2002 to prevent loosening, deterioration, and
electromechanical corrosion of the hardware and joined material.
Note
Cisco NCS 2000 Series Hardware Installation Guide
29
Installing the Air Flow Regulator
NTP-L42 Install the Air Plenum in NCS 2002 Shelf