January 2012 7.4 Switching the Control On/Off 1321
MP_shutdownOnUser
Behavior during switch-off by soft key
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: RESTART
The control is shut down and then restarted.
TERMINATE
The control is shut down, but the operating system remains
active.
SHUTDOWN
The control and the operating system are shut down.
POWEROFF
The control and the operating system are shut down. If a PLC
output is entered in MP_powerOffPort, it will be set after
shutdown.
Default: TERMINATE
Access: LEVEL3
Reaction: NOTHING
MP_shutdownOnOem
Behavior when PLC module 9279 is called
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: RESTART
The control is shut down and then restarted.
TERMINATE
The control is shut down, but the operating system remains
active.
SHUTDOWN
The control and the operating system are shut down.
POWEROFF
The control and the operating system are shut down. If a PLC
output is entered in MP_powerOffPort, it will be set after
shutdown.
Default: TERMINATE
Access: LEVEL3
Reaction: NOTHING