Proceed as follows to assign individual time allowances to M functions:
Create a new key name for the M function's time allowance under
CfgTimeDetMfun.
Declare the M function in MP_mFun and the individual time allowance in
MP_timeAllow. The simulation adds this individual time allowance to the
time allowance from MP_mFunTimeAllow.
Enter the new key name for the time allowance to the list under
CfgmFunKeys/mFunTimeKeys. The new key name is automatically
offered at the very end of the list in the selection menu.
MP_mFunTimeKeys
Key names for M functions with specific time allowances
Format: Array [0...29]
Input: Key names for M functions with specific time allowances.
Default: –
Access: LEVEL1
Reaction: NOTHING
MP_mFun
M function with specific time allowance
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0 to 999
Number of the M function with specific time allowance.
Default: 0
Access: LEVEL1
Reaction: NOTHING
MP_timeAllow
Operating time of the M function
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 to 10 000 000.000 [s]
Operating time of the M function in seconds [s] for the
simulation’s time calculation.
Default: 0 [s]
Access: LEVEL1
Reaction: NOTHING