January 2012 1.2 NC Software 548 328-03 41
Machine
parameters
new/enhanced/
modified
Enhanced/Modified machine parameters:
 
New machine parameters:
MP number Config object Parameter Description of change
100402 CfgFilter MP_typeFilter1 The input range for the maximum 
value of the filter order was increased 
from 31 to 63.
100404 MP_typeFilter2
113102 CfgDashboardElem
nt
/DB_LD_S1
/DB_LD_S2
MP_attribut For spindles, the utilization of the 
rotational speed limit can be displayed 
by setting bit 1 = 1 in MP_attribut; 
See "Configuring dashboards" on page 
1292.
113102 CfgDashboardElem
nt
/DB_OVERRIDE
MP_attribut In the override display of the 
dashboard, the current rapid traverse 
reduction can be displayed by setting 
bit 1 = 1 in MP_attribut; See 
"Configuring dashboards" on page 
1292.
MP 
number
Config object Parameter Description
116104 CfgPlcSymName MP_readTsfData The data for feed rate and spindle 
speed can now be read out by the 
PLC from the "Set T, S, F" dialog; See 
"Transferring the spindle speed and 
feed rate data to the PLC" on page 
1406. 
116105 MP_displayMode The active display mode (e.g. "manual 
control," and "automatic") can now be 
passed on to the PLC; See "Transfer 
display mode to PLC" on page 1406.
116106 MP_setToolPlace By entering a PLC operand, the PLC 
can command the turret position, 
which you would otherwise have to 
set manually; See "MP_setToolPlace" 
on page 1407.