410 HEIDENHAIN Technical Manual MANUALplus 620
CfgMachineSimul
Switch the MANUALplus 620 to the programming station mode;
No drives are enabled. You can create and test NC programs, but you cannot run them. Machine
functions are simulated.
simMode
100201
MP7210
Specifies the type of programming station
mode
Format: Selection menu
Input:
FullOperation:
Programming station mode is switched off.
The wiring of the machine must be complete.
The motors are moving.
CcOnly:
The programming station is active.
Simulation of the CC controller unit. All PLC
inputs and outputs, as well as the emergency-
stop circuit, must be connected correctly in
order to switch the control on correctly.
CcAndExt:
The programming station is active.
Simulation of the CC controller unit and all PLC
inputs and outputs.
Delivery:
Mode for commissioning.
During power-up, all axes are automatically put
into the test mode. The drives cannot be
switched on. In this way, the control can be
started even with an incomplete or faulty axis
configuration.
RESET
LEVEL3
1234
skipReferencing
100202
(optional parameter)
Fast reference run
In programming station mode, the reference run
in the axes can be skipped.
Format: Selection menu
Input:
TRUE:
The axes are set automatically on the reference
positions when the control is started.
FALSE:
Reference run is also active in the programming
station mode.
RESET
LEVEL3
1234
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page

Table of Contents

Other manuals for HEIDENHAIN MANUALPLUS 620