January 2012 4.10 List of Machine Parameters 427
CfgMMISettings
General settings for the Machine mode of operation
extManualMode
604901
(optional parameter)
Enhanced mode for machine operation
Defines the menu guidance of the user interface
(3x3 menu) in the Machine mode of operation.
Format: Selection menu
Input:
TRUE:
The manual cycles are consolidated to the
submode MDI in the user interface.
FALSE:
The Manual cycles are not shown consolidated
in the user interface.
PLC/Pgm
run is
locked
LEVEL1
1229
extProgramMode
604902
(optional parameter)
Enhanced mode for program run
Defines whether a horizontal menu for selecting
additional functions is to be inserted below the
dashboard in the Program Run mode of operation.
Format: Selection menu
Input:
TRUE:
A horizontal menu is displayed below the
dashboard in the Program Run mode.
FALSE:
No horizontal menu shown.
PLC/Pgm
run is
locked
LEVEL1
1229
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.