432 HEIDENHAIN Technical Manual MANUALplus 620
CfgPlcPath
Path/name of most recently compiled PLC program files
mainPgm
102301
Path/name of the PLC main program
Format: String
Input: Path and name, max. 260
characters
NOTHING
LEVEL2
1543
pwmPgm
102302
Path/name of the PLC commissioning
program
PLC program for commissioning the current
controller. This PLC program is alternately
compiled and used if the special mode of
operation for adjusting the current controller is
opened before acknowledgment of the "Power
interrupted" message.
Format: String
Input: Path and name, max. 260
characters
NOTHING
LEVEL2
1543
splcMainPgm
102313
(optional parameter)
Path/name of the SPLC main program
Define only for controls with integrated functional
safety (FS).
NOTHING
LEVEL2
597 110-05
errorTable
102303
Path/name of the PLC error message table
(PET table)
Format: String
Input: Path and name, max. 260
characters
NOTHING
LEVEL2
1543
errorText
102304
Name of the text file for PLC error messages
The path %OEM%\plc\language\en is preset by
the system, whereby the last subdirectory is
formed from the configured language (here en =
English).
Format: String
Input: File name, max. 260 characters
Default: ErrorText.csv
NOTHING
LEVEL2
1543
dialog
102305
Name of text file for PLC dialogs
The path %OEM%\plc\language\en is preset by
the system, whereby the last subdirectory is
formed from the configured language (here en =
English).
Format: String
Input: File name, max. 260 characters
NOTHING
LEVEL2
1544
Parameter
MP number
iTNC MP number