442 HEIDENHAIN Technical Manual MANUALplus 620
code
103905
(optional parameter)
Symbolic name or number of the PLC word
marker for the M code
Name of the PLC word marker in which the M
code is passed to the PLC.
Example: DG_M_Function_M10
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1552
data
103906
Symbolic name or number of the PLC word
marker for additional data
Symbolic name or number of the PLC word
marker in which the additional data of the M
function is transmitted to the PLC.
The field size determined from the symbol defines
up to how many data can be saved in the
programmed sequence. If an absolute number is
given, only one value is saved. If no value is
entered, no data can be passed to the PLC.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1552
revoke
103907
Numbers of M functions whose effect will be
canceled by the output of the strobe.
In the list, enter the numbers of the functions
whose effect will be canceled when this code is
output.
Example: Configuration of M5 function
When the M5 function is called, the effect of the
M3 and M4 functions is canceled. In this example,
you would enter the key names of the functions
M3 and M4.
The parameter is effective for implementing the
state of the function in the status display and
during block scan.
Format: List [0 to 10]
Input: 0 to 9999
RESET
LEVEL3
1552
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page