446 HEIDENHAIN Technical Manual MANUALplus 620
CfgPlcSStrobe
Settings for the S function of a spindle
Output of S strobe from NC to PLC: Specifies the treatment of the S function during NC program run
and the mapping to the PLC markers.
[Key name with the number or name of the spindle]
e.g. S, etc.
type
104017
(optional parameter)
Type of S strobe
If the control supports more than one type of S
strobe for one NC channel, you have to indicate
the type of S strobe applicable for the config
object CfgPlcSStrobes.
If the control supports a single S strobe for an NC
channel, the parameter must not be defined.
Format: Numerical value
Input: 0 to 5
RESET
LEVEL3
1563
condition
104001
(optional parameter)
Condition for sending the strobe to the PLC
Format: Selection menu
Input:
COND_ALWAYS:
Strobe is output with every programmed S code
COND_ST:
Strobe is output only if spindle speed changes
COND_GP:
Strobe is output only if gear range changes If
the parameter is missing from the
configuration, the strobe is always output.
RESET
LEVEL3
1562
signal
104002
(optional parameter)
Symbolic name or number of the PLC marker
that is set when the function is decoded.
If you have not entered a value in the parameter
MP_acknowledge, resetting this marker means
an acknowledgment of the strobe.
No input:
The data connected with the output of the strobe
are saved without synchronization with the PLC
program and the output is immediately
acknowledged.
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1562
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page