January 2012 4.10 List of Machine Parameters 449
sCode
104011
Symbolic name or number of the PLC word for
the coded output of the spindle speed
Name of the PLC word in which the S code of the
spindle speed is transmitted to the PLC
Format: String
Input: PLC operand, max. 80 characters
RESET
LEVEL3
1572
revoke
104012
(optional parameter)
Numbers of functions whose effect will be
canceled by the output of the strobe.
In the list, enter the numbers of the functions
whose effect will be canceled when this code is
output.
The parameter is effective for implementing the
state of the function in the status display and
during block scan.
Format: List [0 to 10]
Input: 0 to 9999
RESET
LEVEL3
1565
singular
104013
(optional parameter)
Function is output in a separate strobe
With the "singular" parameter you can prevent the
function from being output in a strobe together
with other functions. If several M, S, T functions
are programmed in an NC block, the strobes can
be set in parallel by the NC. With this parameter,
you can exclude the current function from this
parallel collection and simultaneous transmission
in one strobe.
Format: Selection menu
Input:
TRUE:
Function is output in a separate strobe.
Combined output is prevented.
FALSE:
Function can be combined with other functions
RESET
LEVEL3
1565
blockSearch
104014
Code output also during block scan
Format: Selection menu
Input: TRUE or FALSE
TRUE:
Function is also output during the block scan
FALSE:
Function is not output during the block scan.
The function is collected and restored.
Default: FALSE
RESET
LEVEL3
1566
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page