January 2012 4.10 List of Machine Parameters 465
TableSettings
Description of the table types of the MANUALplus 620;
Specifies the properties of the tables.
CfgTableProperties
Assignment of columns to a table type; Specifies:
The columns in the table
The primary and foreign key
With this information you can import a table or create a new one.
[Key name with the file extension of the table]
E. g. CMA, COM, TCH, etc.
columnKeys
105501
List of key names of the columns used
Key names of all columns that form the table. The
column names must be available under Columns.
Format: List [0 to 79]
Input: Column name, max. 18 characters
PLC/Pgm
run is
locked
LEVEL3
1598
primaryKey
105502
Primary key (column name) for sorting
Name of the column, based upon which the data
is sorted in ascending order. The column name
must be available under CfgTableProperties/
[key name]/columnKeys.
Format: String
Input: Column name, max. 18 characters
PLC/Pgm
run is
locked
LEVEL3
1598
foreignKey
105503
(optional parameter)
Foreign key for this table
Specify a string for every list entry:
<column name> <blank space> <referential
action>
Valid values for <referential action>are:
NO ACTION
RESTRICT
SET NULL
SET DEFAULT
INHERIT
Format: List [1 to 80]
Input: String, max. 40 characters
PLC/Pgm
run is
locked
LEVEL3
1598
modificationKey
105504
(optional parameter)
Key name of the column in which the
timestamp is to be entered if a line is modified
Format: String
Input: <extension>.<column name>
Max. 18 characters
PLC/Pgm
run is
locked
LEVEL3
1598