464 HEIDENHAIN Technical Manual MANUALplus 620
resetNcTimes
105003
MP7237.2
Reset NC operating times with code number
857282
Format: Bit-encoded value
Input: %xxx
Bit 0 to bit 2
= NC time 1 to 3
Bit 0 – Nonfunctional
Bit 1 – "Machine on" operating time
Bit 2 – "Program run" operating time
0: Do not reset
1: Reset
PLC/Pgm
run is
locked
LEVEL2
1374
textNumber
105004
MP7238
Dialogs for PLC operating times
Lists 0 to 7, field 0 is the text for PLC time 1.
In the text file for PLC dialogs, indicate the line
number of the dialog text. This text file is located
under %OEM%\plc\language\en, whereby the
last subdirectory is formed from the configured
language (here en=English).
Format: List [0 to 7]
Input: 0 to 2147483647
PLC/Pgm
run is
locked
LEVEL2
1375
CfgSystemTime
Universal time (Greenwich Mean Time)
offsetToUTC
105201
MP7235
Time difference to universal time
This is used in the real-time system (HeROS).
Difference to universal time (UTC: Universal Time
Coordinated), e.g. UTC+1h for Central European
Time (CET)
Format: Selection menu
Input: Time difference from UTC
UTC–10h, UTC–9h, UTC–8h,
UTC–7h, UTC–6h, UTC–5h,
UTC–4h 30min, UTC–4h,
UTC–3h, UTC–2h, UTC–1h,
UTC,
UTC+1h, UTC+2h, UTC+3h,
UTC+4h, UTC+5h,
UTC+5h 30min,
UTC+6h, UTC+7h, UTC+8h,
UTC+9h, UTC+9h 30min,
UTC+10h, UTC+11h, UTC+12h
Default: UTC+1h (CET)
RESET