504 HEIDENHAIN Technical Manual MANUALplus 620
tStrobes
201603
List of T strobe descriptions in this channel
Format: List [0 to 3]
Input: Key name of the T function
Selection from CfgPlcTStrobe
RESET
LEVEL3
1574
aliasStrobes
201604
List of implemented strobes in this channel
Reproduction of control-dependent functions on a
uniform M-function transfer to the PLC program.
Format: List [0 to 5]
Input: Key name of the M function
Selection from CfgPlcMStrobe
RESET
LEVEL3
1582
unitOfMeasure
201605
(optional parameter)
Symbolic name or number of the PLC marker for
the unit of measure of the NC program
Name of the PLC marker that informs the PLC of
the unit of measure of the NC program to be run.
PLC marker = 1: Inches
PLC marker = 0: Metric system
Format: String
Input: Max. 24 characters
RESET
LEVEL3
1548
CfgPlcOverrideF
Configuration of the feed rate override for this channel
minimal
201901
Minimum value for override
Format: Numerical value
Input: 0.00 to 100.00 [%]
Default: 0 [%]
RESET
LEVEL3
1357
maximal
201902
Maximum value for override
Format: Numerical value
Input: 0.00 to 200.00 [%]
Default: 150 [%]
RESET
LEVEL3
1357
source
201903
Source for override values
Format: List [0 to 2]
Input: Key name of the override device
from
CfgPlcOverrideDev
RESET
LEVEL3
1357
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page