536 HEIDENHAIN Technical Manual MANUALplus 620
CfgReferencing
Axis parameters for the reference run;
For rotary axes and spindles, the velocity is specified in [°/min].
refType
400401
MP1350
Sequence for finding the reference mark
Format: Selection menu
Input:
None:
No traversing of the reference mark.
If the reference run with the spindle is
performed via a trip dog, this value must be set.
Switch, changing Dir:
For linear axes with speed encoder; reference
run with NC start
Switch, no changing Dir:
For linear axes with speed encoder; reference
run with NC start
without Switch:
For spindle, rotary table with angle encoder;
reference run with NC start
distance coded:
For distance-coded linear encoders; reference
run with NC start
distance coded + on the fly:
For distance-coded linear encoders; reference
run with axis-direction keys or NC start
without switch + on the fly:
For spindle; reference run with M3, M4
Endat Encoder:
For axes with EnDat encoder; reference-mark
traverse not necessary
Default: Switch, changing Dir
RUN
LEVEL3
798
endatSerial
400402
(optional parameter)
Connecting incremental encoders via the EIB
Format: Selection menu
Input:
TRUE:
An incremental encoder is connected to the
serial EnDat 2.2 interface via the EIB.
FALSE:
No EIB is used.
RUN
LEVEL3
647
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page