552 HEIDENHAIN Technical Manual MANUALplus 620
vCtrlEncInputFilt
400906
MP2560.x, MP2561.x
Filter order of the FIR filter (low-pass filter)
Format: Numerical value
Input: 0 to 20
0: No low-pass filter
1: 1st-order low-pass filter
...
20: 20th-order low-pass filter
Default: 0
Allowed in
strobe
LEVEL 3
861
vCtrlFiltType1
400907
MP2562.x
(optional parameter)
Filter type for filter 1
Format: Numerical value
Input: 0: Filter deactivated
1: PT2 low-pass (speed ctrl.)
2: Band-rejection filter (speed ctrl.)
3: Phase increase (speed ctrl.)
11: PT2 low-pass (position ctrl.)
12: Band-rejection filter (position
ctrl.)
13: Phase increase (position ctrl.)
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltFreq1
400908
MP2550,x, MP2551.x,
MP2552.x
Center frequency of the band-rejection filter
for filter 1
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltBandWidth1
400909
MP2572.x
(optional parameter)
Bandwidth of band-rejection filter for filter 1
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltDamping1
400910
MP2540.x, MP2541.x
MP2542.x
Damping the band-rejection filter for filter 1
Format: Numerical value
Input: 0.000 000 000 to 40 [dB]
Default: 0
Allowed in
strobe
LEVEL 3
860
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access