January 2012 4.10 List of Machine Parameters 553
vCtrlFiltType2
400911
MP2563.x
(optional parameter)
Filter type for filter 2
Format: Numerical value
Input: 0: Filter deactivated
1: PT2 low-pass (speed ctrl.)
2: Band-rejection filter (speed ctrl.)
3: Phase increase (speed ctrl.)
11: PT2 low-pass (position ctrl.)
12: Band-rejection filter (position
ctrl.)
13: Phase increase (position ctrl.)
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltFreq2
400912
MP2553.x
(optional parameter)
Center frequency of the band-rejection filter
for filter 2
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltBandWidth2
400913
MP2573.x
(optional parameter)
Bandwidth of band-rejection filter for filter 2
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltDamping2
400914
MP2543.x
(optional parameter)
Damping the band-rejection filter for filter 2
Format: Numerical value
Input: 0.000 000 000 to 40 [dB]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltType3
400915
MP2564.x
(optional parameter)
Filter type for filter 3
Format: Numerical value
Input: 0: Filter deactivated
1: PT2 low-pass (speed ctrl.)
2: Band-rejection filter (speed ctrl.)
3: Phase increase (speed ctrl.)
11: PT2 low-pass (position ctrl.)
12: Band-rejection filter (position
ctrl.)
13: Phase increase (position ctrl.)
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltFreq3
400916
MP2554.x
(optional parameter)
Center frequency of the band-rejection filter
for filter 3
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default:
0
Allowed in
strobe
LEVEL 3
860