554 HEIDENHAIN Technical Manual MANUALplus 620
vCtrlFiltBandWidth3
400917
MP2574.x
(optional parameter)
Bandwidth of the band-rejection filter for filter
3
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltDamping3
400918
MP2544.x
(optional parameter)
Damping the band-rejection filter for filter 3
Format: Numerical value
Input: 0.000 000 000 to 40 [dB]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltType4
400919
MP2565.x
(optional parameter)
Filter type for filter 4
Format: Numerical value
Input: 0: Filter deactivated
1: PT2 low-pass (speed ctrl.)
2: Band-rejection filter (speed ctrl.)
3: Phase increase (speed ctrl.)
11: PT2 low-pass (position ctrl.)
12: Band-rejection filter (position
ctrl.)
13: Phase increase (position ctrl.)
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltFreq4
400920
MP2555.x
(optional parameter)
Center frequency of the band-rejection filter
for filter 4
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrFiltBandWidth4
400921
MP2575.x
(optional parameter)
Bandwidth of the band-rejection filter for filter
4
Format: Numerical value
Input: 0.000 000 000 to 5000 [Hz]
Default: 0
Allowed in
strobe
LEVEL 3
860
vCtrlFiltDamping4
400922
MP2545.x
(optional parameter)
Damping the band-rejection filter for filter 4
Format: Numerical value
Input: 0.000 000 000 to 40 [dB]
Default: 0
Allowed in
strobe
LEVEL 3
860
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page

Table of Contents