564 HEIDENHAIN Technical Manual MANUALplus 620
ampAdditionalInfo
401210
(optional parameter)
Configure the switch position of the current
sensor (column S of the inverter.inv power
module table).
Is required for the D series of HEIDENHAIN
inverters (UM 1xx D) in order to use the higher
currents at the lower PWM frequencies.
Format: Bit-encoded value (32 bits)
Input:
Bit 0 – Configure the switch position of the
current sensor in HEIDENHAIN inverters of the
"D" series (UM 1xx D).
0: Column S in inverter.inv table = 0
1: Column S in inverter.inv table = 1
Bit 1 – Reserved
Bit 2 – Reserved
Bit 3 – Inverter manufacturer:
0: Non-HEIDENHAIN inverter
1: HEIDENHAIN inverter
Bit 4 to bit 31 – Reserved
Default:
RUN
LEVEL3
597 110-04
1075
CfgServoMotor
Specifies the settings for the motor
motName
401301
MP2200.x
Name of the motor
Format: Selection menu
Input: Name of the motor from the
motor table
(is entered by the MANUALplus
620)
RUN
LEVEL3
1056
starDelta
401302
Motor with wye/delta switchover
Format: Selection menu
Input:
star-connection:
Wye connection
delta-connection:
Delta connection
Default: star-connection
RUN
LEVEL3
936
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page