January 2012 4.10 List of Machine Parameters 579
CfgProbePosition
Definition of the touch probe positions
positionProbePos
604701
Positive position of probe/optics
Position of the touch probe (or optical gauge) in
positive axis direction with respect to the machine
datum
Format: Numerical value
Input: Positive position in [mm] with up to
9 decimal places
RUN
LEVEL3
1386
positionProbeNeg
604702
Negative position of probe/optics
Position of the touch probe (or optical gauge) in
negative axis direction with respect to the
machine datum
Format: Numerical value
Input: Negative position in [mm] with up
to
9 decimal places
RUN
LEVEL3
1386
maxMeasuringFeed
604703
Maximum measuring feed
Maximum permissible feed rate for traverse to
the touch probe
Format: Numerical value
Input: Max. feed rate in [mm] with up to
9 decimal places
RUN
LEVEL3
1387
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page