January 2012 6.10 Axis Error Compensation 717
How to access the tables:
 Switch to the Organization operating mode.
 Press the   soft key.
 Enter the code number 95148.
 Press the PGMMGT soft key (drive PLC: becomes visible).
 In the PLC:/table drive, open the tables *.COM and *.CMA.
Entries:
Axis Y:
Screw-pitch 
error in Y axis, 
sag error in 
Z axis
Axis Z:
Screw-pitch 
error in Z axis