To connect each QFX3008-I Interconnect Device to the control plane network (see Figure
84 on page 279:
1. Connect the first Interconnect device.
a. Connect one end of the first RJ-45 patch cable to the first SFP management port
(labeled 0) on the first Control Board (labeled CB 0).
b. Connect the other end of that cable to port ge-0/0/39 on the first Virtual Chassis.
c. Connect one end of the second RJ-45 patch cable to the second SFP management
port (labeled 1) on the first Control Board (labeled CB 0).
d. Connect the other end of that cable to port ge-0/0/39 on the second Virtual Chassis.
e. Connect one end of the third RJ-45 patch cable to the first SFP management port
(labeled 0) on the second Control Board (labeled CB 1).
f. Connect the other end of that cable to port ge-1/0/39 on the first Virtual Chassis.
g. Connect one end of the fourth RJ-45 patch cable to the second SFP management
port (labeled 1) on the second Control Board (labeled CB 1).
h. Connect the other end of that cable to port ge-1/0/39 on the second Virtual Chassis.
2. Connect the second Interconnect device.
a. Connect one end of the first RJ-45 patch cable to the first SFP management port
(labeled 0) on the first Control Board (labeled CB 0).
b. Connect the other end of that cable to port ge-2/0/39 on the first Virtual Chassis.
c. Connect one end of the second RJ-45 patch cable to the second SFP management
port (labeled 1) on the first Control Board (labeled CB 0).
d. Connect the other end of that cable to port ge-2/0/39 on the second Virtual Chassis.
e. Connect one end of the third RJ-45 patch cable to the first SFP management port
(labeled 0) on the second Control Board (labeled CB 1).
f. Connect the other end of that cable to port ge-3/0/39 on the first Virtual Chassis.
g. Connect one end of the fourth RJ-45 patch cable to the second SFP management
port (labeled 1) on the second Control Board (labeled CB 1).
h. Connect the other end of that cable to port ge-3/0/39 on the second Virtual Chassis.
Related
Documentation
Connecting a QFX3500 Node Device to the Control Plane Network on page 282
Connecting a QFX3500 Node Device to a QFX3008-I Interconnect Device on page 284
Connecting QFX3100 Director Devices to the Control Plane Network on page 275
Connecting QFX3100 Director Devices in a Director Group on page 274
281Copyright © 2012, Juniper Networks, Inc.