To connect each QFX3008-I Interconnect Device to the control plane network (see Figure
84 on page 279:
1. Connect the first Interconnect device.
a. Connect one end of the first RJ-45 patch cable to the first SFP management port
(labeled 0) on the first Control Board (labeled CB 0).
b. Connect the other end of that cable to port ge-0/0/39 on the first Virtual Chassis.
c. Connect one end of the second RJ-45 patch cable to the second SFP management
port (labeled 1) on the first Control Board (labeled CB 0).
d. Connect the other end of that cable to port ge-0/0/39 on the second Virtual Chassis.
e. Connect one end of the third RJ-45 patch cable to the first SFP management port
(labeled 0) on the second Control Board (labeled CB 1).
f. Connect the other end of that cable to port ge-1/0/39 on the first Virtual Chassis.
g. Connect one end of the fourth RJ-45 patch cable to the second SFP management
port (labeled 1) on the second Control Board (labeled CB 1).
h. Connect the other end of that cable to port ge-1/0/39 on the second Virtual Chassis.
2. Connect the second Interconnect device.
a. Connect one end of the first RJ-45 patch cable to the first SFP management port
(labeled 0) on the first Control Board (labeled CB 0).
b. Connect the other end of that cable to port ge-2/0/39 on the first Virtual Chassis.
c. Connect one end of the second RJ-45 patch cable to the second SFP management
port (labeled 1) on the first Control Board (labeled CB 0).
d. Connect the other end of that cable to port ge-2/0/39 on the second Virtual Chassis.
e. Connect one end of the third RJ-45 patch cable to the first SFP management port
(labeled 0) on the second Control Board (labeled CB 1).
f. Connect the other end of that cable to port ge-3/0/39 on the first Virtual Chassis.
g. Connect one end of the fourth RJ-45 patch cable to the second SFP management
port (labeled 1) on the second Control Board (labeled CB 1).
h. Connect the other end of that cable to port ge-3/0/39 on the second Virtual Chassis.
Related
Documentation
Connecting a QFX3500 Node Device to the Control Plane Network on page 282
Connecting a QFX3500 Node Device to a QFX3008-I Interconnect Device on page 284
Connecting QFX3100 Director Devices to the Control Plane Network on page 275
Connecting QFX3100 Director Devices in a Director Group on page 274
281Copyright © 2012, Juniper Networks, Inc.
Chapter 22: Cabling the QFabric Switch

Table of Contents

Other manuals for Juniper QFX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX Series and is the answer not in the manual?

Juniper QFX Series Specifications

General IconGeneral
CategorySwitch
SeriesQFX
Form Factor1U, 2U, and modular chassis options
Power SupplyRedundant, hot-swappable power supplies
Coolinghot-swappable fans
Virtual ChassisSupported on certain models
Typical UseData center, cloud
Operating SystemJunos OS
ManagementCLI
Key FeaturesHigh performance, low latency, automation
LatencySub-microsecond latency
Port DensityVaries by model (e.g., QFX5100: up to 48x10GbE + 6x40GbE)

Related product manuals