Page 120 Data entry/Programming Group 7
Release R1.12 en JET2 neo
Automatic clock change (Summer-/Wintertime)
Automatic change is switched off
Automatic change is switched on
1 – Register card <Date/Time>
2 – Control box <Summer-/Wintertime>
7.2.3.1.3 Interval operation (Set interval time)
The mode <Interval operation> enables the input of start- and end times when the
LEIBINGER JET2neo urns on or off automatically (e.g. 10.20 pm, the device turns on /
10.40 pm, the device turns off). to circulate the ink.
This function prevents that the ink dries up or sediments as well as the jamming of the
nozzle if the printer is turned off for a longer time.
As standard the interval operation is carried out without viscosity control. In case of need
the viscosity control can be also activated for the interval operation.
Attention! The viscosity control should be only activated for special
operating conditions of the JET2neo or after consultation with the
LEIBINGER-service department.
You should set an interval time of at least 20 minutes.
Press on the register card <Interval> (1) to select the functional area.
Press on the display window <Interval on> (2). A setting block (4) opens.