Group 5 Transport/Start up Page 33
JET2 neo Release R1.12 en
Please note, that the grounding point (6) is hidden behind the round
grounding-symbol-label (7) on the lower left hand side of the cabinet of the
printer.
Figure 6
Grounding schematic and grounding point
Grounding schematic
ground / earth
1 Printer cabinet
4 Grounding line
7 Grounding symbol
2 Installation (machine)
5 Umbilical
(label)
3 Print head
6 Grounding point (M6)
Grounding instructions
A separate grounding line (min. cable cross-section 2.00 mm
2
) to the printer cabinet
must be installed before the print head is mounted in the installation and before the
printer is plugged to the power supply.
The connection must be carried with a solid bonding that corresponds with existing
guidelines.
Annotation: A suitable grounding cable is available optionally (accessories).
The installation (machine) and the printer must have the same potential/ground.
5
7
4
6
1
3
2
(earth)

Table of Contents