EasyManua.ls Logo

Leibinger JET2neo - Figure 127 Monitoring Functions; Monitoring Functions

Leibinger JET2neo
294 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 200 Job editor Group 8
Release R1.12 en JET2 neo
8.5.2.2.3 Monitoring functions
Two monitoring functions are available. Monitoring functions are especially required for
high printing speeds.
Figure 127
Monitoring functions
PrintGo-monitoring:
If the function is activated it is monitored if every Print-Go signal can be
processed.If a signal can be not processed, a certain error message is generated.
Example:
A PrintGo is generated and is printed. The next PrintGo is generated; if the printing
process is not finished yet, an error message is generated on the display.
StrokeGo-monitoring:
If the function is activated, the stroke output is monitored, that means if the
StrokeGo-signal is generated faster than the printer can output the several strokes,
an error message is also generated.
Example:
If the production speed with the set parameters is too high, stroke errors can be caused.
The following error message appears on the display: