Group 9 Malfunctioning/Trouble shooting Page 257
JET2 neo Release R1.12 en
Figure 152
Device messages
Warning messages
Error messages
1 Warning text
3 Error text
2 Balance time (Count down timer)
4 Button <Confirm>
9.3 Error messages
Error
no.
Error message
Reason of failure
Workaround
5000
Charging electrode is dirty
Charging electrode is dirty.
Clean charging electrode
5001
Phasing error
Charging electrode is dirty.
Clean charging electrode
5002
Error of drop control
Charging electrode is dirty.
Wrong frequency has been set.
Oscillator is defect.
Clean charging electrode
Change frequency
Exchange oscillator
5003
Error of oscillator voltage
Bad drop control point.
Charging electrode is dirty.
Wrong frequency has been set.
Oscillator is defect.
Clean charging electrode
Change frequency
Exchange oscillator
5020
HV-current too high.
Please check deflection
plates for dirt or damp-ness.
Dirt at the deflection plates.
Dampness at the deflection
plates.
Clean deflection plates
Dry deflection plates
5060
Overload of the charging
voltage amplifier.
Overload of charging voltage
amplifier.
Clean charging electrode
1309
Ink return monitoring
2
3
4
1
4

Table of Contents