Adjusting the Images That Were Taken
FQ2-S/CH User’s Manual
119
3
Taking Images
• Detailed Settings for Two-edge Midpoint Compensation
The settings for the Two-edge Midpoint Compensation item are almost the same as those for the Edge Position
inspection item.
Make the settings in the same way as for the Edge Position inspection item.
4-12 Inspecting with the Edge Position Inspection Item: p. 271
However, the following settings are included only in the Edge Position Compensation Item.
• Teaching
Set the measurement regions and measurement directions for both edge 0 and edge 1.
[Image] [Image adjustment] [2Edge midpoint comp.] [Modify] [Basic] [Teach]
The settings are the same as those for the Two-edge Position Compensation item.
Teaching: p. 115
• Source Image
You can select the image to which to apply the results of position compensation processing.
Applying the Results of Position Compensation: p.104
• Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image] [Image adjustment] [2ed. midp. comp.] [Modify] [Details] [Scroll parameter]
[Interpolation]
The settings are the same as those for the Shape Search Position Compensation item.
Interpolation: p. 108

Table of Contents