Menu Tables
FQ2-S/CH User’s Manual
459
Appendices
9
Inspection
Details
(Area*
2
)
Meas. Parameter
Fill profile You can set how to process holes for
an Area inspection item.
None (Default)
Filling up holes
Fill Outline
Scene p. 308
Output parameter
Reflect
You can specify whether to reflect the
judgement results of an inspection
item in the overall judgement.
No
Yes (Default) Scene p. 319
(Labeling*
2
)
Meas. Parameter
Filling up holes Sets how to process areas surrounded
by the specified color.
Yes
No (Default)
Scene p. 308
Extract image
Select this option if there are areas of
the specified color inside the measure-
ment region that you do not want to
measure.
Yes
No (Default)
Scene p. 317
Extraction condi-
tion
Scene
p. 317
Number of
labels
Set the maximum number of labels to
detect.
Range: 1 to 100
Default: 100
Scene
Area Specify the area range to judge as a
label.
Range: 0 to 999,999,999.9999
(Defaults:
Lower limit: 0
Upper limit: 999,999,999.9999)
Scene
Gravity X Specify the gravity X position to judge
as a label.
Range: 99,999,999.9999 to
999,999,999.999
(Defaults:
Lower limit: 0
Upper limit: 999,999,999.9999)
p. 218
Gravity Y Specify the gravity Y position to judge
as a label.
Range: 999,999,999.9999 to
999,999,999.999
(Defaults:
Lower limit: 0
Upper limit: 999,999,999.9999)
Sorting method Set the condition to use for label num-
ber reassignment.
Area ascending order
Area descending order (Default)
Pos. X ascending order
Pos. X descending order
Pos. Y ascending order
Pos. Y descending order
Scene p. 319
Output parameter
Reflect
You can specify whether to reflect the
judgement results of an inspection
item in the overall judgement.
No
Yes (Default) Scene p. 319
Menu command Description Setting range Data