USING THE DEBUG LOG
B079/B082 5-100 SM
To save data for item 3 (an SC code), press .
COPY : SP-5-858-001
Debug Save When
Any SC Error
670
Enter the 3 digits for the SC error code then press . For details about SC
code numbers, please refer to the SC tables in Section “4. Troubleshooting”.
Selecting a Module for Retrieval
Specific error information related to a particular module can be selected for
retrieval.
NOTE: SP5859 (Debug Save Key No.) allows you to define up to 10 keys. More
than one key can be set.
1. Enter  then press .
2. Under “5859” press the number of the key that you want to define. The
example below shows the screen after “1” is pressed to define “Key 1”.
COPY : SP-5-859-001
Debug Save Key No.
Key 1
_
3. Enter a number for the key.
COPY : SP-5-859-001
Debug Save Key No.
Key 1
2222
4. Press to save the key definition.