SP2-XXX (Drum) -1
D0CA/D0C9/D0C8/D0CB 3-62 SM Appendices
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
2-194-01
0
MUSIC Execution Result Error Result: C ENG
*
[0 to 9 / 0 /
1/step]
2-194-011 MUSIC Execution Result Error Result: M ENG
*
[0 to 9 / 0 /
1/step]
2-194-01
2
MUSIC Execution Result Error Result: Y ENG
*
[0 to 9 / 0 /
1/step]
2-194-01
3
MUSIC Execution Result Error Result: Bk ENG
*
[0 to 9 / 0 /
1/step]
2-221-00
1
LD Power: Fixed: Set Standard Speed: Bk ENG
*
[0 to 255 / 100
/ 1%/step]
2-221-00
2
LD Power: Fixed: Set Standard Speed: C ENG
*
[0 to 255 / 100
/ 1%/step]
2-221-00
3
LD Power: Fixed: Set Standard Speed: M ENG
*
[0 to 255 / 100
/ 1%/step]
2-221-00
4
LD Power: Fixed: Set Standard Speed: Y ENG
*
[0 to 255 / 100
/ 1%/step]
2-221-011 LD Power: Fixed: Set Low Speed: M ENG
*
[0 to 200 / 100
/ 1%/step]
2-221-01
2
LD Power: Fixed: Set Low Speed: Y ENG
*
[0 to 200 / 100
/ 1%/step]
2-229-00
1
Develop DC Bias: Fixed Standard Speed: Bk ENG
*
[0 to 800 / 450
/ 1-V/step]
2-229-00
2
Develop DC Bias: Fixed Standard Speed: C ENG
*
[0 to 800 / 450
/ 1-V/step]
2-229-00
3
Develop DC Bias: Fixed Standard Speed: M ENG
*
[0 to 800 / 450
/ 1-V/step]
2-229-00
4
Develop DC Bias: Fixed Standard Speed: Y ENG
*
[0 to 800 / 450
/ 1-V/step]
2-241-00
3
PCDU Temperature: Display Time Interval: Fan
Extension Control
ENG
*
[1 to 300 / 10 /
1sec/step]
2-241-00
4
PCDU Temperature: Display PCDU Temperature ENG [0.0 to 70.0 /
0.0 /
0.1deg/step]
2-242-00
1
TS Operation Env. Log Distance: PCU: Bk:
TS<=A-3
ENG [0 to
99999999 / 0 /
1mm/step]